IECEx ATEX zone 2 UL class I, division 2 HMI panel PC hazardous areasAIS offers 15-22" rugged monitor IEx standard and compact series with international approvals for operation and monitoring in hazardous areas with modular designs. AIS rugged monitor IEx series are constructed with completely sealed stainless steel type 4/4X, IP 65/66, NEMA 4/4X enclosure with environmental ratings (UL 50 or IEC 529) on the entire HMI monitor including fully sealed I/O ports. The rugged industrial display supports wide operating temperatures from -20 to +60°C. AIS offers OSHA’s NEC Class I Division 2, Groups A, B, C, D, T4, CENELEC’s ATEX 94/9/EC Zone 2, IEC’s IECEx Zone 2, Ex nA and Ex ic certification on its hazardous locations rugged displays and open HMI platforms which are primarily designed for the volatile and harsh environments of oil, gas, chemicals, and oilfield equipment and services.

IPC and HMI technology for hazardous areasBrochure: 
Rugged IPC and HMI technology for hazardous areas and extreme environments in the oil and gas industry. Learn more »

White Paper:
 This technical paper will explore the basics of fire and explosion safety issues, legislation, regulations and standards around the world, and compare the Class/Division Hazardous Location versus Zone Hazardous Area Classifications and Protections primarily for Oil & Gas Refineries, Chemical Processing and Transport Operations. Addressing Hazardous Areas Safety Requirements with Properly Designed Intrinsically Safe and Ex Approved HMIs and Industrial Monitors Solutions for the Oil & Gas Industry. Learn more »


Benefits

  • UL Listed to Safety Standards: ANSI/ISA 12.12.01, 2012, Nonincendive Industrial Monitor and Display for Use in Class 1, Division 2 Groups A, B, C, D Hazardous (Classified) Locations and CAN/CSA C22.2 No. 213-M1987 for Use in Class 1, Division 2 Hazardous Locations: UL File # E365958
  • UL Listed to Safety Standards: UL 60950-1 and CSA C22.2 No. 60950-1-07: UL File # E320439
  • CE Ex Marked to Safety Standards: Explosive Atmospheres (ATEX)-Directive 94/9/EC-Complying with the Essential Health and Safety Requirements that relate to the design of Zone 2 Category 3 Industrial Monitor and Display, certified to ATEX Protection Classes- “CE Ex mark” II 3 G Ex nA ic IIA T4
  • Compliance with the Essential Health and Safety Requirements has been assured by Compliance with IEC 60079-0, IEC 60079-11, and IEC 60079-15
  • The Hazardous Areas Monitors and Displays are particularly suitable for operator control and monitoring, measuring and testing as well as data collection, communication and other applications close to the machine in hazardous zones 2

Standard Monitor IEx

AIS offers 15-22" standard monitor IEx with international approvals for operation and monitoring in hazardous areas with modular designs. The rugged industrial display supports wide operating temperatures from -20 to +60°C. AIS offers OSHA’s NEC Class I Division 2, Groups A, B, C, D, T4, CENELEC’s ATEX 94/9/EC Zone 2, IEC’s IECEx Zone 2, Ex nA and Ex ic certification on its hazardous locations rugged displays and open HMI platforms which are primarily designed for the volatile and harsh environments of oil, gas, chemicals, and oilfield equipment and services.

Compact Monitor IEx

AIS offers 15” compact monitor IEx with international approvals for operation and monitoring in hazardous areas. The rugged industrial display supports wide operating temperatures from -20 to +50°C. AIS offers OSHA’s NEC Class I Division 2, Groups A, B, C, D, T4, CENELEC’s ATEX 94/9/EC Zone 2, IEC’s IECEx Zone 2, Ex nA and Ex ic certification on its hazardous locations rugged displays and open HMI platforms which are primarily designed for the volatile and harsh environments of oil, gas, chemicals, and oilfield equipment and services.